High Quality Programmable Simulated Environment Laboratory
Equipment 1000L Temperature Humidity Chamber Product Description: 1000L Laboratory Temperature Humidity Chambers can do
constant temperature and humidity testing ,temperaturing
resistanceing ,humdity resistance testing for electronic products
and other products . this temperature humidity chamber be with
1000L internal testing chamber.This very spacious size of the
testing of the box is very suitable for multi-functional laboratory
and large products company's QC QA detection with different
sizes of products. Application industry (not limited to the following): - electronic, electrical, mobile, data
- communication, instrumentation, vehicle parts
- Plastic products, metal, food
- Chemistry, building materials, medical treatment
- Space and other products to detect the quality of use
Function and Features: - The Temperature Humidity Chambers is mainly used in testing
the adaptability of electronics, electrical appliances, food,
automobile, rubber and plastic, metal and other products, parts and
materials in the high and low temperature alternating hot and humid
environment when storage, transport and using;
- Temperature Humidity Chambers is an reliable test equipment for all
kinds of electronic, electrical, electronics, plastics raw
materials and devices to do testing such as cold, heat, moisture,
resistance to dry and the quality control ;
- Especially suitable for optical fiber, LCD, crystal, inductor, PCB,
batteries, computers, mobile phones, rubber, plastics and other
product.
- The new perfect design, the appearance of high texture level, the
system extracts Japan, West Germany, the essence of design and
manufacture of advanced technology.
- Balanced temperature humidity control system (BTHC), to PID mode
control SSR, so that heated humidification system was equal to heat
loss capacity, it could be used long-term stability;
- All-capillary, automatic load capacity adjustment system
technology, more expansion valve system more stable and reliable,
precise temperature and humidity control, heating and cooling rate
of rapid, steady, uniform, saving valuable time for users.
Parameters: Inspect standard:JJF-1101,GB/T 10592,GB/T 10586 Testing standards:YD/T 2061,HB 7122.3,6783.7,GJB 5382.7,GJB 150,GB/T
2423,5170.2,5170.5,5179.2, ASTM E512,NF EN 60068-2-38,CNS
12565,12566,KS C0227,KS C022 Standard Features: Item | Specification | Internal dimension | (W*H*D) 1000x1000x800mm | External dimension | (W*H*D) 1550x2100x1400mm | Temperature range | -70~+150℃ | Temp. & Humid. deviation | ±0.5℃,±2%RH | Humidity range | 20~98%R.H. (Refer Image below) | Temp. & Humid. average difference | ±2℃,±3%RH | Cooling speed | 0.7~1.2℃/min | Heating speed | ≤2.5℃/min | Internal chamber material | SUS#304 stainless steel, mirror finished | External chamber material | Stainless steel with paint spray | Cooling method | Air cooling | Controller | LCD touch screen, programmable control temperature and humidity Can set different parameter for cyclic test | Insulation material | 50mm high density rigid Polyurethane foam | Heater | Explosion-proof type SUS#304 stainless steel fins radiator pipe
heater | Compressor | France Tecumseh compressor | Lighting | Heat resistance | Temperature sensor | PT-100 dry and wet bulb sensor | Observation window | Tempered glass | Testing hole | Diameter 50mm, for cable routing | Safety protection device | Protection for leakage Over-temperature Compressor overvoltage and overload Heater short circuit Water shortage |
The original device configuration: Exterior material | SUS#304 Stainless steel | Interior material | SUS#304 cold-roll steel sheets with rust prevention or SUS#304
Stainless steel plate | Insulation Material | PU foam and fiberglass | Moist material | Glass fiber | Heaters | Nicochrome Stainless steel pipe heater | Humidification pipe | Evaporation occurs stainless steel electric mode of the U-shaped
humidifier | Air circulation system | 60W high temperature motor, Wind round stainless steel multi-wing,
special air circulation system with adjustable. | Door | Singer door,Window 280mm×265mm×40 mm three vacuum layers | Box | Foshan Photo | Water tank | Stainless steel water tank,Automatic pump,Alarm device of water
shortage ,Water shortage alarm,Stop to protect when long water
shortage. | Main electrical components | Taiwan Adventist AC contactor,Thermal relay,Time Relay,OMRON AC
relay, Three controller Korea,Italian dry protector etc. | Safety devices | water protection,water shutdown protection,high-pressure compressor
protection,compressor thermal protection,compressor overload.
protection,fast fuse,buzzer alarm,overload protection. |
Cooling system and heating system: Compressor | Tecumseh of France, all closed. | Refrigerant | R23 / R404A Environmental protection refrigerant (DuPont of USA) | Condenser | Air Force Taiwan Kuwait shell and tube condenser | Evaporator | Taiwan Kuwait force fins multi zone automatic load capacity
adjustment | Expansion of the system | capacity control of cooling system | Refrigeration Service parts | all imported electromagnetic valve (Japan, "Heron House), the
pressure controller (Danfoss), the oil separator (Danfoss) and
other cooling accessories |
Control system: - Heating and cooling mode:PID constant way of cooling capacity to
control SSR, larger than the cooling capacity of the heating
temperature, heat flux less than the cooling capacity of the
cooling
- Normal mode:Balanced temperature humidity control system (BTHC), to
PID mode control SSR, so that heated humidification system is equal
to amount of heat and moisture loss
- The temperature and humidity controller:Controller using the
controller: South Korea imported "TEMI" 880-type film type keypad
programmable LCD display PID temperature controller, a 100 group
program memory 1200 paragraphs, together with groups of PID
control.
Installation environment: - Temperature:0℃~35℃
- Relative humidity:≤85%
- Atmospheric pressure:86kPA~106kPa
- Installation site should be ground flat,and ventilation.
- Equipment without a strong vibration around.
- No strong magnetic fields affect the surrounding equipment.
- The equipment around the non-flammable, explosive, corrosive
substances, and dust
- Left around the proper use of equipment and maintenance of space.
|