Discharge Current 15KA Power Supply Surge Protector SGS Approved
|
255/275/320/385VAC Power Surge Protection Device For Power Supply |
Model: OBV10-I-15-Pluggable | |||
Maximum continuous operating voltage | Uc | V | 255/275/320/385 |
SPD to EN 61643-11 | Type 1 | ||
SPD to IEC 61643-1 | class I | ||
LPZ | 0→2 | ||
Lightning impulse current (10/350μs) | Iimp | kA | 15 |
Lightning impulse current (10/350μs) [total] | kA | 60 | |
Nominal discharge surge current (8/20μs) | In | kA | 60 |
Maximum discharge surge current (8/20μs) | Imax | kA | 100 |
Voltage protection level | Up | kV | 2,5 |
Response time | tA | ns | <25 |
Follow current quenching capacity Ipeak | Ifi peak | kA | 12.5 |
Maximum back-up fuse | A | 315 | |
Temperature range | ϑ | °C | -40℃~+85℃ |
Protection rating | IP 20 | ||
Connection cross-section, rigid | mm² | 10-50 | |
Connection cross-section, multi-wire | mm² | 10-35 | |
Connection cross-section, flexible | mm² | 10-25 |
Feature&Benefits
1,Protect electric system and on-loading electrical apparatus from
thunder and instantaneous over-voltage.
2,Protect transmission of Ethernet signals with 48V DC / 34V AC
power supply circuits against
lightning induced surges.
3,Enhanced surge protection.
4,For mounting on 35mm DIN rails acc. to EN 60715.
5,It can effectively ensure the equipments work properly.
·Easy installation or retrofit.
·Din-rail mountable.
·Fail-safe /self-protected designRemote indicator (optional) with
3pin NO/NC contact.
·IP20 finger-safe designVisual indicator.
·Small foot print.
Application
●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
Others
Technology SPD parameter(Note:According to user requirement ,can be
customized Uc=140V,440V,550V,voltage range of range of the SPD):
Type No. | Rated Voltage(V) Un | Continuous Voltage Uc(V~) | Standard Discharge Current In(KA) | Max Discharge Current | Protection Level(KA~) | Response Time(ns) |
DGM1(2)-D5 | 220/380 | 275/320 | 5 | 10 | 1.2 | ≤25 |
DGM1(2)-D10 | 10 | 2 | 1.6 | |||
DGM1(2)-C20 | 20 | 40 | 1.8 | |||
DGM13-B30 | 30 | 60 | .2.2 | |||
DGM3(4)-B40 | 10 | 80 | 2.4 | |||
DGM(4)-B60 | 60 | 100 | 2.8 | |||
DGM-N-PE | 220/255 | 40/60 | 60/80 | 1.2 | ≤100 |
Transient voltage surgesin lv power lines
Transient overvoltages are voltage surges that can reach tens
ofkilovolts with a duration of the order of microseconds.Despite
theirshort duration, the high energy content can cause serious
problemsto equipment connected to the line, from premature aging to
destruction, causing disruptions to service and financial
loss.Thistype of surge can have various different causes, including
atmospheric lightning directly striking the external
protection(lightning rods) on a building or transmission line or
the associatedinduction of electromagnetic fields on metallic
conductors.
Outdoor and longer lines are the most exposed to these fields,which
often receive high levels of induction.
It is also common for non-weather phenomena, such as transformer
centre switching or the disconnection of motors orother inductive
loads to cause voltage spikes in adjacent lines.
Although a lower current is induced,the effect produced is equally or moredestructive, due to the greatersensitivity of electronic equipmentconnected to communications lines(telephone, Ethernet, R, etc.).
Importance of theground connection
Overvoltage protectors (SPD) divert excess energy toground, so
limiting the peak voltage to an acceptablevalue for connected
electrical equipment.
A ground connection in adequate condition is, therefore,a key
aspect for effective protection against overvoltages.Monitoring
ground connection condition guaranteesproper operation of surge
protection devices.
External protection (ESE lightning rods and faradization).System for protection against direct lightningstrike.These capture the lightning within the protectedarea and lead it, in a controlled manner, safely to ground. Internal protection (power frequency overvoltage andsurge protection devices). Equipment designed to protectagainst the effects of overvoltages in equipment connected to the power supply systems and/orcommunications networks.Grounding systems (grounding and insulation monitoring).Systems that allow atmospheric dischargecurrents to be dispersed into the ground. The need formonitoring the grounding system.CUAJE offers a widerange of products for each of these systems. It alsodevelops custom products, provides advice and consultingservices and the best possible aftersales service.
First of all, you must determine what your power distribution system is like, whether it is TT, TN or IT system. After determining the power distribution system, you can choose the protection mode and wiring method of the lightning arrester to select the appropriate lightning arrester.
For example, TN-C uses 3P lightning protection device, TN-S uses 4P, TT uses 3P+N, etc.
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are
available.
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.
![]() |
Intelligent Lightning Counter LC Surge Protector Breaker IP20 Enclosure Rating |
![]() |
Un Nominal Working Voltage 1000V Surge Protector Breaker 35mm Slide Guide |
![]() |
Outdoor Building Floor Surge Protection Device SPD Low Voltage 200 / 380VAC |
![]() |
48V Three Level Surge Protector SPD Smallest Size Single Phase |
![]() |
Secondary Power Surge Protector SPD 60kA With Fast Response Time |
![]() |
Red Thermoplastic Housing Surge Protector SPD 120kA Secondary |